Beam Detector
| Feature | Details |
|---|---|
| Product Name | Beam Detector |
| Type | Optical Beam Smoke Detector |
| Detection Method | Infrared light beam interruption |
| Range | Up to 100 meters (model dependent) |
| Function | Detects smoke over large open areas |
| Installation | Wall-mounted (transmitter & receiver) |
| Compatibility | Conventional & Addressable systems |
| Indication | LED / controller status display |
| Application | Warehouses, malls, factories |
Description
A Beam Detector, also known as an Optical Beam Smoke Detector, is a specialized fire detection device designed for large open areas where traditional point-type smoke detectors may not be effective. It operates using an infrared light beam transmitted from a sender unit to a receiver unit (or a reflector). Under normal conditions, the beam remains uninterrupted; however, when smoke enters the path of the beam, it reduces the signal strength, triggering an alarm condition.
Beam detectors are ideal for environments such as warehouses, factories, shopping malls, airports, atriums, and high-ceiling buildings where wide coverage is required. They can monitor large distances—typically up to 100 meters—making them a cost-effective solution by reducing the number of detectors needed in expansive spaces.
These detectors can be configured as either end-to-end systems (separate transmitter and receiver) or reflective systems (transmitter/receiver with a reflector). Many modern beam detectors include features such as automatic alignment, dust compensation, and adjustable sensitivity to minimize false alarms and ensure reliable performance in challenging environments.
Compatible with both conventional and addressable fire alarm systems, beam detectors provide efficient and early smoke detection over large areas. Their robust design, long-range capability, and advanced sensing technology make them an essential component in modern fire safety systems for large infrastructures.
Related products
Addressable Fire Alarm System
| Feature | Details |
|---|---|
| System Type | Addressable Fire Alarm System |
| Coverage | Device-level identification |
| Detection | Smoke, heat, flame detectors, MCP |
| Installation | Advanced and scalable |
| Ideal For | Large buildings & complex facilities |
| Indication | Exact device location detection |
| Maintenance | Easy fault detection & monitoring |
Conventional Fire Alarm System
Inspire Fire Alarm Control Panel
| Feature | Details |
|---|---|
| Product Name | INSPIRE Fire Alarm Control Panel |
| Type | Intelligent Addressable Fire Alarm Panel |
| Brand | Notifier by Honeywell |
| System Capacity | Up to 3,180 addressable devices |
| Loop Capacity | 1 to 10 SLC loops |
| Display | 10-inch color touchscreen |
| Design | Modular & scalable architecture |
| Connectivity | Network-enabled (LAN/WAN, cloud-ready) |
| Integration | Voice evacuation & firefighter telephone |
| Application | Small to large infrastructure |
ISO-X Isolator Module
| Feature | Details |
|---|---|
| Model | ISO-X Isolator Module |
| Type | Fault Isolator Module |
| Brand | Notifier (Honeywell) |
| Function | Protects SLC loop from short circuits |
| Power Supply | Powered directly from SLC loop |
| Indication | LED status indicator |
| Compatibility | ONYX & CLIP series panels |
| Wiring Support | Style 4, 6, 7 |
| Application | Addressable fire alarm systems |
MCP Manual Call Point
| Feature | Details |
|---|---|
| Product Name | MCP (Manual Call Point) |
| Type | Fire Alarm Activation Device |
| Function | Manual fire alarm triggering |
| Operation | Break glass / push button |
| Mounting | Wall-mounted |
| Compatibility | Conventional & Addressable systems |
| Voltage | Typically 12V / 24V DC |
| Application | All types of buildings |
| Color | Red (standard fire safety color) |
MM500 Monitor Module
| Feature | Details |
|---|---|
| Model | MPM-300 Monitor & Control Module |
| Type | Addressable Monitor & Control Module |
| Brand | Notifier / Honeywell |
| Function | Monitors input devices & controls output devices |
| Power Supply | Powered via SLC loop |
| Communication | Addressable (rotary switch addressing) |
| Wiring | Class A & Class B support |
| Indication | LED status (normal & alarm) |
| Application | Fire alarm system integration |
NFS2-3030 NFC Fire Alarm Control Panel
| Feature | Details |
|---|---|
| Model | NFS2-3030 NFC Fire Alarm Control Panel |
| Type | Intelligent Addressable Fire Alarm Panel |
| Series | ONYX Series (Notifier – Honeywell) |
| Loop Capacity | 1 to 10 SLC loops |
| Device Capacity | Up to 3,180 addressable devices |
| Display | 640-character LCD |
| Communication | LAN/WAN networking compatible |
| Integration | NFC (Notifier First Command) voice & emergency system |
| Application | Large & complex buildings |
| Special Feature | Advanced intelligent sensing & degraded mode |
Optical Smoke Detector
| Feature | Details |
|---|---|
| Product Name | Optical Smoke Detector |
| Type | Photoelectric Smoke Detector |
| Detection Method | Light scattering (infrared sensor) |
| Function | Detects visible smoke particles |
| Power Supply | 12V / 24V DC (system dependent) |
| Compatibility | Conventional & Addressable systems |
| Indication | LED status (alarm & normal) |
| Application | Indoor fire detection |
| Installation | Ceiling-mounted |