| Feature | Details |
|---|---|
| Product Name | MCP (Manual Call Point) |
| Type | Fire Alarm Activation Device |
| Function | Manual fire alarm triggering |
| Operation | Break glass / push button |
| Mounting | Wall-mounted |
| Compatibility | Conventional & Addressable systems |
| Voltage | Typically 12V / 24V DC |
| Application | All types of buildings |
| Color | Red (standard fire safety color) |
Description
An MCP (Manual Call Point) is a critical fire alarm device used to manually activate a fire alarm system in case of an emergency. It allows building occupants to immediately raise an alarm when they detect smoke, fire, or any hazardous situation, even before automatic detectors respond. Typically installed on walls near exits, staircases, and escape routes, the MCP ensures quick and easy access during emergencies.
The device operates through a simple mechanism—either by breaking a glass element or pressing a resettable button—which sends a signal directly to the fire alarm control panel. Once activated, the system triggers audible and visual alarms across the premises, enabling rapid evacuation and emergency response.
Manual Call Points are available in both conventional and addressable types. In conventional systems, activation indicates the zone, whereas in addressable systems, the exact location of the triggered MCP is displayed on the panel for precise identification.
Designed as per international fire safety standards such as EN54 and IS codes, MCPs are built using durable, fire-retardant materials to ensure long-term reliability. Their simple design, ease of installation, and vital role in emergency situations make them an indispensable component of any fire detection and alarm system.
Related products
Beam Detector
| Feature | Details |
|---|---|
| Product Name | Beam Detector |
| Type | Optical Beam Smoke Detector |
| Detection Method | Infrared light beam interruption |
| Range | Up to 100 meters (model dependent) |
| Function | Detects smoke over large open areas |
| Installation | Wall-mounted (transmitter & receiver) |
| Compatibility | Conventional & Addressable systems |
| Indication | LED / controller status display |
| Application | Warehouses, malls, factories |
Conventional Fire Alarm System
Inspire Fire Alarm Control Panel
| Feature | Details |
|---|---|
| Product Name | INSPIRE Fire Alarm Control Panel |
| Type | Intelligent Addressable Fire Alarm Panel |
| Brand | Notifier by Honeywell |
| System Capacity | Up to 3,180 addressable devices |
| Loop Capacity | 1 to 10 SLC loops |
| Display | 10-inch color touchscreen |
| Design | Modular & scalable architecture |
| Connectivity | Network-enabled (LAN/WAN, cloud-ready) |
| Integration | Voice evacuation & firefighter telephone |
| Application | Small to large infrastructure |
ISO-X Isolator Module
| Feature | Details |
|---|---|
| Model | ISO-X Isolator Module |
| Type | Fault Isolator Module |
| Brand | Notifier (Honeywell) |
| Function | Protects SLC loop from short circuits |
| Power Supply | Powered directly from SLC loop |
| Indication | LED status indicator |
| Compatibility | ONYX & CLIP series panels |
| Wiring Support | Style 4, 6, 7 |
| Application | Addressable fire alarm systems |
MM500 Monitor Module
| Feature | Details |
|---|---|
| Model | MPM-300 Monitor & Control Module |
| Type | Addressable Monitor & Control Module |
| Brand | Notifier / Honeywell |
| Function | Monitors input devices & controls output devices |
| Power Supply | Powered via SLC loop |
| Communication | Addressable (rotary switch addressing) |
| Wiring | Class A & Class B support |
| Indication | LED status (normal & alarm) |
| Application | Fire alarm system integration |
NFS2-3030 Fire Alarm Control Panel
| Feature | Details |
|---|---|
| Model | NFS2-3030 Fire Alarm Control Panel |
| Type | Intelligent Addressable FACP |
| Series | ONYX Series (Notifier / Honeywell) |
| Loop Capacity | 1 to 10 SLC loops |
| Device Capacity | Up to 3,180 addressable devices |
| Display | 640-character LCD display |
| Application | Medium to large buildings |
| Networking | Supports LAN/WAN networking |
| Detection | Advanced intelligent sensing |
| Expansion | Modular & scalable design |
NFS2-3030 NFC Fire Alarm Control Panel
| Feature | Details |
|---|---|
| Model | NFS2-3030 NFC Fire Alarm Control Panel |
| Type | Intelligent Addressable Fire Alarm Panel |
| Series | ONYX Series (Notifier – Honeywell) |
| Loop Capacity | 1 to 10 SLC loops |
| Device Capacity | Up to 3,180 addressable devices |
| Display | 640-character LCD |
| Communication | LAN/WAN networking compatible |
| Integration | NFC (Notifier First Command) voice & emergency system |
| Application | Large & complex buildings |
| Special Feature | Advanced intelligent sensing & degraded mode |
Optical Smoke Detector
| Feature | Details |
|---|---|
| Product Name | Optical Smoke Detector |
| Type | Photoelectric Smoke Detector |
| Detection Method | Light scattering (infrared sensor) |
| Function | Detects visible smoke particles |
| Power Supply | 12V / 24V DC (system dependent) |
| Compatibility | Conventional & Addressable systems |
| Indication | LED status (alarm & normal) |
| Application | Indoor fire detection |