Conventional Fire Alarm System
| Feature | Details |
|---|---|
| System Type | Conventional Fire Alarm System |
| Coverage | Divided into multiple zones |
| Detection | Smoke, heat, and manual call points |
| Installation | Simple and cost-effective |
| Ideal For | Small to medium buildings |
| Indication | Zone-based fire identification |
| Maintenance | Easy to maintain and operate |
Description
A Conventional Fire Alarm System is a reliable and cost-effective fire detection solution designed primarily for small to medium-sized buildings such as offices, schools, retail shops, and warehouses. This system operates by dividing the premises into multiple zones, allowing users to identify the general area where a fire has occurred. Each zone is connected to a control panel, which receives signals from devices such as smoke detectors, heat detectors, and manual call points.
When a fire is detected, the system triggers an alarm and indicates the affected zone on the control panel, enabling quick response and evacuation. Although it does not pinpoint the exact device location like addressable systems, it provides sufficient accuracy for many applications. Conventional fire alarm systems are known for their simple installation, user-friendly operation, and low maintenance requirements, making them an ideal choice for budget-conscious projects without compromising on safety.
Related products
Addressable Fire Alarm System
| Feature | Details |
|---|---|
| System Type | Addressable Fire Alarm System |
| Coverage | Device-level identification |
| Detection | Smoke, heat, flame detectors, MCP |
| Installation | Advanced and scalable |
| Ideal For | Large buildings & complex facilities |
| Indication | Exact device location detection |
| Maintenance | Easy fault detection & monitoring |
Beam Detector
| Feature | Details |
|---|---|
| Product Name | Beam Detector |
| Type | Optical Beam Smoke Detector |
| Detection Method | Infrared light beam interruption |
| Range | Up to 100 meters (model dependent) |
| Function | Detects smoke over large open areas |
| Installation | Wall-mounted (transmitter & receiver) |
| Compatibility | Conventional & Addressable systems |
| Indication | LED / controller status display |
| Application | Warehouses, malls, factories |
ISO-X Isolator Module
| Feature | Details |
|---|---|
| Model | ISO-X Isolator Module |
| Type | Fault Isolator Module |
| Brand | Notifier (Honeywell) |
| Function | Protects SLC loop from short circuits |
| Power Supply | Powered directly from SLC loop |
| Indication | LED status indicator |
| Compatibility | ONYX & CLIP series panels |
| Wiring Support | Style 4, 6, 7 |
| Application | Addressable fire alarm systems |
MCP Manual Call Point
| Feature | Details |
|---|---|
| Product Name | MCP (Manual Call Point) |
| Type | Fire Alarm Activation Device |
| Function | Manual fire alarm triggering |
| Operation | Break glass / push button |
| Mounting | Wall-mounted |
| Compatibility | Conventional & Addressable systems |
| Voltage | Typically 12V / 24V DC |
| Application | All types of buildings |
| Color | Red (standard fire safety color) |
MM500 Monitor Module
| Feature | Details |
|---|---|
| Model | MPM-300 Monitor & Control Module |
| Type | Addressable Monitor & Control Module |
| Brand | Notifier / Honeywell |
| Function | Monitors input devices & controls output devices |
| Power Supply | Powered via SLC loop |
| Communication | Addressable (rotary switch addressing) |
| Wiring | Class A & Class B support |
| Indication | LED status (normal & alarm) |
| Application | Fire alarm system integration |
NFS2-3030 Fire Alarm Control Panel
| Feature | Details |
|---|---|
| Model | NFS2-3030 Fire Alarm Control Panel |
| Type | Intelligent Addressable FACP |
| Series | ONYX Series (Notifier / Honeywell) |
| Loop Capacity | 1 to 10 SLC loops |
| Device Capacity | Up to 3,180 addressable devices |
| Display | 640-character LCD display |
| Application | Medium to large buildings |
| Networking | Supports LAN/WAN networking |
| Detection | Advanced intelligent sensing |
| Expansion | Modular & scalable design |
NFS2-3030 NFC Fire Alarm Control Panel
| Feature | Details |
|---|---|
| Model | NFS2-3030 NFC Fire Alarm Control Panel |
| Type | Intelligent Addressable Fire Alarm Panel |
| Series | ONYX Series (Notifier – Honeywell) |
| Loop Capacity | 1 to 10 SLC loops |
| Device Capacity | Up to 3,180 addressable devices |
| Display | 640-character LCD |
| Communication | LAN/WAN networking compatible |
| Integration | NFC (Notifier First Command) voice & emergency system |
| Application | Large & complex buildings |
| Special Feature | Advanced intelligent sensing & degraded mode |
Optical Smoke Detector
| Feature | Details |
|---|---|
| Product Name | Optical Smoke Detector |
| Type | Photoelectric Smoke Detector |
| Detection Method | Light scattering (infrared sensor) |
| Function | Detects visible smoke particles |
| Power Supply | 12V / 24V DC (system dependent) |
| Compatibility | Conventional & Addressable systems |
| Indication | LED status (alarm & normal) |
| Application | Indoor fire detection |
| Installation | Ceiling-mounted |